Amperage Europe 230 V 2,9 A (650W) America 120 V 5.5 A(650 W) Protection Type IP22
Power supply Europe 230 V / 0-60 Hz America 120 V / 0-60 Hz Max. Housing Surface Temperature 220° C
Switch on the fixture M.O. & P.O. Toggle : 16A\125V - 8A\250V Weight of Fixture M.O. 2,4 kg. / P.O. 4,7 kg.
Lamp Holder GY 9,5 Weight of Barndoor 4 leaf 0,3 kg. / 8 leaf 0,4 kg.
Europe 3 x 1,5 mm2 – 150°C(0,5 m silicon 180 °C + Size of Barndoor ring Diameter 192 mm
3m H07RN-F 90°C) Weight of color frame 0,25 kg.
Power Cable America 3 x 16 Awg(0,5 m high T 200°C + 3m SO Size of scrims & color frame Diameter 129 mm.
90°C + Plug Lens diameter 120 mm.
Protection Class Class 1– ground connection required
WORKING CONDITIONS
Working Position Lighting fixture : Max. Tilting ±90° from horizontal Lamp: S90
AmbientTemperature,t +45° C Max
ᵅ
Minimum distances from inflammable surfaces Top 0,3 m. Back 0,1 m. Sides 0,1 m. Front 1 m.
PHOTOMETRIC DATA MAGIS (300 W LAMP)
Values measured with: CP 81 Lamp - 200 V, 120 mm, F.Fresnel Lens
FEET METERS
TYPICAL DISTANCES 10’ 20’ 30’ 40’ 3,0 6,0 9,0 12,0
LIGHT CENTER VALUES Candle Power Footcandles Lux
SPOT 27.000 270 68 30 17 3.000 750 333 188
FLOOD 3.250 33 8 4 2 361 90 40 23
F.C. AT ANY DISTANCE = Candle Power : LUX. AT ANY DISTANCE =
BEAM ANGLE (50% of center value) (distance in ft)2 Candle Power : (distance in ft)2
BEAM SIZE (W x H in feet) BEAM SIZE(W x H in meters)
SPOT 7,2° 1.3’ 2.5’ 3.8’ 5.0’ 0,4 mt 0,8 mt 1,1 mt 1,5 mt
FLOOD 51,5° 9.6’ 19.3’ 28.9’ 38.6’ 2,9 mt 5,8 mt 8,7 mt 11,6 mt
FIELD ANGLE (10% of center value) BEAM SIZE (W x H in feet) BEAM SIZE(W x H in meters)
SPOT 15,5° 2.7’ 5.4’ 8.2’ 10.9’ 0,8 mt 1,6 mt 2,4 mt 3,3 mt
FLOOD 64,5° 12.6’ 25.2’ 37.9’ 50.5’ 3,8 mt 7,6 mt 11,4 mt 15,1 mt
PHOTOMETRIC DATA MAGIS (500 W LAMP)
Values measured with: CP 82 Lamp – 220 V, 120 mm. F Fresnel Lens
FEET METERS
TYPICAL DISTANCES 10’ 20’ 30’ 40’ 3,0 6,0 9,0 12,0
LIGHT CENTER VALUES Candle Power Footcandles Lux
SPOT 42.030 420 105 47 26 4.670 1.168 519 292
FLOOD 3.250 59 15 7 4 650 163 72 41
F.C. AT ANY DISTANCE = Candle Power : LUX. AT ANY DISTANCE =
BEAM ANGLE (50% of center value) (distance in ft)2 Candle Power : (distance in ft)2
BEAM SIZE (W x H in feet) BEAM SIZE(W x H in meters)
SPOT 7,2° 1.4’ 2.8’ 4.2’ 5.6’ 0,4 mt 0,8 mt 1,3 mt 1,7 mt
FLOOD 51,5° 9.9’ 19.8’ 29.7’ 39.6’ 3,0 mt 5,9 mt 8,9 mt 11,9 mt
FIELD ANGLE (10% of center value) BEAM SIZE (W x H in feet) BEAM SIZE(W x H in meters)
SPOT 15,5° 3.0’ 5.9’ 8.9’ 11.9’ 0,9 mt 1,8 mt 2,7 mt 3,6 mt
FLOOD 64,5° 11.9’ 23.8’ 35.8’ 47.7’ 3,6 mt 7,2 mt 10,7 mt 14,3 mt
Values measured with: CP 81 Lamp - 200 V, 120 mm, F.Fresnel Lens
FEET METERS
TYPICAL DISTANCES 10’ 20’ 30’ 40’ 3,0 6,0 9,0 12,0
LIGHT CENTER VALUES Candle Power Footcandles Lux
SPOT 77.994 780 195 87 49 4.670 1.168 519 292
FLOOD 11.250 113 28 13 7 650 163 72 41
F.C. AT ANY DISTANCE = Candle Power : LUX. AT ANY DISTANCE =
BEAM ANGLE (50% of center value) (distance in ft)2 Candle Power : (distance in ft)2
BEAM SIZE (W x H in feet) BEAM SIZE(W x H in meters)
SPOT 7,2° 1.4’ 2.8’ 4.2’ 5.6’ 0,4 mt 0,8 mt 1,3 mt 1,7 mt
FLOOD 51,5° 8.7’ 17.4’ 26.2’ 34.9’ 2,6 mt 5,2 mt 7,8 mt 10,5 mt
FIELD ANGLE (10% of center value) BEAM SIZE (W x H in feet) BEAM SIZE(W x H in meters)
SPOT 15,5° 2.8’ 5.7’ 8.5’ 11.3’ 0,8 mt 1,7 mt 2,5 mt 3,4 mt
FLOOD 64,5° 11.4’ 22.8’ 34.2’ 45.6’ 3,4 mt 6,8 mt 10,3 mt 13,7 mt